UV aging test chamber

Another name:

Describe:UV Aging Test Chamber, also known as UV Aging Test Chamber or UV Aging Testing Machine, simulates the harm caused by sunlight and dew to materials and products, and is widely used for evaluating the weather resistance of materials< Using an imported intelligent temperature and humidity controller for temperature and humidity control,

Consultation

Details

1、 Product Introduction

UV aging test chamber, also known as UV Aging test chamber or UV Aging Testing Machine, simulates the harm caused by sunlight and dew to materials and products, and is widely used for evaluating the weather resistance of materials< Using an imported intelligent temperature and humidity controller for temperature and humidity control, with PID regulation and fast self-tuning, multiple parameters can be set, and temperature and humidity are directly displayed digitally, making reading extremely convenient; The inner liner material is made of stainless steel, and the overall appearance is beautiful and generous& nbsp;< br/>

2、 Execution standards and testing methods

 

1 GB/T 16422.3,GB/T5170.9

2 GB/T 164423.3~1997

3. Applicable to ASTM G154

 

3、 Specification and model

ModelWS-UV-1/WS-UV-2
Internal dimensions45x110x50cm
performancetemperature rangeRoom temperature 10 ℃+70 ℃
Temperature fluctuation≤±0.5℃
Humidity range95%~100%RH
External dimensions50x130x148cm
Environmental temperature for use+5℃~+35℃
Experimental light sourceUV-A/B ultraviolet lamp
Experimental light source wavelength280~400nm
Sample rack size150x75x1.5cm
Center distance between sample and lamp tube50mm±2mm
Distance between the lamp tube and the center of the lamp tube                70mm±2mm
                Material Science  studioBrushed stainless steel
ShellBrushed stainless steel
Heating humidifierElectric heating steam generates heat and humidifies
safety systemOperation interfaceDigital intelligent touch key input (programmable)
Operation modeProgrammable/Constant Operation
Set RangeBy temperature range
inputBlackboard thermometer PT-100 sensor
Supplementary functionsUpstream and offline alarm, alarm display, timer function
Standard accessories20 stainless steel sample racks
Security configurationLeakage, overload and power-off protection, over temperature protection, water shortage, and ground contact protection
Use power supply220V±1%,50HZ
powerthree

 < br/>

Main technical parameters
temperature range10 ℃~+70 ℃ (no light conditions)Remarks:< br/> 1. All under empty container conditions (except as indicated), tested according to GB/T5170
2. The test data of the air-cooled test chamber system was tested under good ventilation conditions at room temperature of 25 ℃; When 35 ℃ ≥ room temperature>25 ℃, it can be used normally, but the low temperature range, cooling rate, and thermal load capacity will be affected to some extent< br/> 3. Test data of water-cooled test chamber under the conditions of water temperature ≤ 28 ℃, water pressure between 0.2MPa and 0.6MPa, and inlet and outlet water pressure difference ≥ 0.2MPa
                Temperature fluctuation≤± 0.5 ℃ (no light conditions)
Temperature uniformity≤ 2 ℃ (no light conditions)
Temperature deviation± 2 ℃ (no light conditions)
Humidity range40% to 98% RH (under no light conditions) (see humidity range chart)
Humidity deviation+2~-3%(>75%RH),
± 5% (≤ 75% RH) (under no light conditions)
Heating time≤ 60 minutes (room temperature~+70 ℃)
Light intensity(700-1120) ± 10% W/m2 (adjustable)
Light exposure time1   Adjustable from 0 to 99 hours and 99 minutes
During the irradiation period, the temperature inside the test chamber should rise at a rate close to linear and remain at the set temperature control value (typical settings are+55 ℃ and 40 ℃). During the shutdown phase, the temperature inside the test chamber should decrease at a rate close to linear to the set temperature control value (typical setting value is+25 ℃) and maintain temperature stability. The relationship between temperature, irradiation, and time during different experimental procedures is shown in Figure 2.
Spectral energy distribution and tolerance: should meet the requirements in Table 1
Test timeCan be set within 0-999 hours, Can automatically conduct experiments according to the following test procedures:
Test Procedure A: With a 24-hour cycle, irradiation for 8 hours and 16 hours off, the test period can be set
Test Procedure B: The test cycle is set to 24 hours, with 20 hours of irradiation and 4 hours of shutdown. The test cycle can be adjusted.
Test Procedure C: Continuous irradiation, test time can be set.
Lamp coolingAir cooling (under normal usage conditions, the effective service life of metal halide lamp tubes is 800-1000 hours)
wind speedThe wind speed of the test chamber can be adjusted within the range of 0.5-1.5m/s through a frequency converter;
Attached with the equipment manual is a comparison table of wind speed and frequency converter.
Spectral energy distribution and tolerance: should meet the requirements in Table 1
                                Spectrum areaUltraviolet BUltraviolet Avisible lightinfrared
Bandwidth um0.28~0.320.32~0.400.40~0.520.52~0.640.64~0.780.78~3.00
Radiation intensity W/m2fivesixty-threetwo hundredone hundred and eighty-sixone hundred and seventy-fourfour hundred and ninety-two
Tolerance%±35±25±10±10±10±20
 